2-14 Sun StorEdge 3000 Family FRU Installation Guide • May 2004
a. Align the top and bottom edges of each cap with the top and bottom edges of
each chassis ear.
b. While holding the side of the chassis with one hand, push the cap onto the ear
with the other hand. Be sure to place the cap with LED labels on the right ear.
Caution – Do not use force when placing a cap on an ear.
10. Insert the bezel arms into the chassis holes, and then lift and push the bezel onto
the front of the chassis and use the key to lock it in place.
2.3.2 Converting a Tabletop Array to a Rack-Ready
Array
Perform the following steps to convert a tabletop array to a rack-ready array.
1. If attached, remove the bezel front cover by pulling it forward and downward.
Then press the right bezel arm (hinge) towards the left side to release it from the
chassis hole. The left hinge will release also. Note the location of the chassis bezel
holes on each ear.
2. Remove the caps from the front left and right ears of the array by squeezing and
pressing each cap towards the center of the chassis until it is free.
3. Remove the 10-32 x 1/4-inch Phillips panhead screws which attach the tabletop
cover to the array, with a Phillips No. 2 screwdriver, and discard these screws.
4. On the top of the array, remove the top two back center black flathead 4-40 x 1/4-
inch screws with a Phillips No. 1 screwdriver and keep these screws.
5. Pull the front of the chassis until the chassis is completely removed from the
tabletop cover.
6. Re-insert and secure the two black screws from Step 4 into the top center back of
the rack-ready array with a Phillips No. 1 screwdriver.
7. Follow the rack kit installation instructions of the rackmount kit to install the
array into a rack. After the RAID product is mounted in the rack, you can re-
install the caps onto the ears and the bezel onto the front of the RAID product;
these steps are also included in the rack kit instructions.