Chapter 6 SCSI Module FRUs 6-13
a. Connect to the array console menu interface via the serial interface (tip for
Solaris/Linux) or via telnet.
b. From the Main Menu, choose “view and edit Configuration parameters,” then
“Controller Parameters.”
c. Select “Controller Unique Identifier (hex).”
17. If this array is being used by clustered hosts, or for any other reason its attached
hosts require that their Device IDs remaining consistent, perform these steps:
a. Set Controller Unique Identifier (hex) to the value you wrote down in step 2.
b. Reset the RAID Controllers: From the Main Menu, choose “system Functions,”
then “Reset controller.” Confirm Yes when prompted.
c. Proceed with step 19.
18. If this array is NOT being used by clustered hosts, perform these steps:
a. On the firmware main menu, choose “view and edit Configuration
parameters,” then choose “Controller Parameters,” and press Return.
b. From the Controller Parameters menu, choose “Controller Unique Identifier
<hex>” and press Return.
c. Type in the value 0 (to automatically read the chassis serial number from the
midplane).