setdualpowerfeed(8)
System Administration 187
NAME setdualpowerfeed - set dual power feed mode
SYNOPSIS setdualpowerfeed -s key
setdualpowerfeed -h
DESCRIPTION The setdualpowerfeed(8) command specifies dual power feed mode in the
system.
The setdualpowerfeed(8) command is available on the M3000/M4000/M5000
servers only. On the M8000/M9000 servers, when the power cabinet for dual power
feed connected, it automatically configures the dual power feed mode.
To enable the dual power feed mode, you need to execute the rebootxscf(8)
command or turn off and on the input power.
To disable the dual power feed mode, you need to turn off and on the input power.
Privileges You must have platadm or fieldeng privileges to run this command.
Refer to setprivileges(8) for more information.
OPTIONS The following options are supported:
EXTENDED
DESCRIPTION
The state of the current dual power feed mode can be checked by using the
showdualpowerfeed(8) command.
EXAMPLES
EXAMPLE 1 Disables dual power feed mode in the system. Before rebooting the system, a
message is displayed.
EXAMPLE 2 Enables dual power feed mode in the system. Before rebooting the system, a
-h Displays usage statement. When used with other options or
operands, an error occurs.
-s key Sets dual power feed mode in the system. Either of the following
can be specified for key:
enable Enables the dual power feed mode.
disable Disables dual power feed mode.
XSCF> setdualpowerfeed -s disable
enable -> disable
NOTE: Dual power feed will be disabled the next time the platform is powered
on.