showlogs(8)
398 SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
EXAMPLE 4 Displays a power log.
EXAMPLE 5 Displays a power log in the order of timestamps, starting from the latest
timestamp.
EXAMPLE 6 Displays the specified range of a power log.
Msg: offline(vendor=FUJITSU, product=MAJ3182MC)
Diagnostic Code:
00112233 44556677 8899aabb
00112233 44556677 8899aabb ccddeeff
00112233 44556677 8899aabb ccddeeff
UUID: bf36f0ea-9e47-42b5-fc6f-c0d979c4c8f4 MSG-ID: FMD-8000-11
Diagnostic Messages
Jul 11 16:17:42 plato10 root: [ID 702911 user.error] WARNING: /
pci@83,4000/scsi@2/sd@0,0 (sd47):
Jul 11 16:17:42 plato10 root: [ID 702911 user.error] incomplete write-
giving up
XSCF>
showlogs power
Date Event Cause DID Switch
Mar 30 17:25:31 JST 2005 System Power Off Power Failure -- Service
Mar 30 17:35:31 JST 2005 System Power On AC Restored -- Locked
Mar 30 17:45:31 JST 2005 Domain Power Off Operator 00 Locked
Mar 30 17:50:31 JST 2005 Domain Power On Operator 00 Service
XSCF> showlogs power -r
Date Event Cause DID Switch
Mar 30 17:50:31 JST 2005 Domain Power On Operator 00 Service
Mar 30 17:45:31 JST 2005 Domain Power Off Operator 00 Locked
Mar 30 17:35:31 JST 2005 System Power On AC Restored -- Locked
Mar 30 17:25:31 JST 2005 System Power Off Power Failure -- Service
XSCF> showlogs power -t Mar3017:302005 -T Mar3017:492005
Date Event Cause DID Switch
Mar 30 17:35:31 JST 2005 System Power On AC Restored -- Locked
Mar 30 17:45:31 JST 2005 Domain Power Off Operator 00 Locked