Page #60 background imageLoading...
Page #60 background image
Page | 60
SUNSYNK MAX | User Manual
Aux Load off Battery
% or Voltage
Battery level when the Aux load switches off
Aux Load on Battery
% or Voltage
Battery level when the Aux load switches on.
Solar Power Power limiter to the maximum power allowed to the Aux load.
Gen Input Tick this box if using a Generator.
Aux Load Output Tick this box if using an Aux or Smart Load.
For Micro inverter
Input
Tick this box if intending to connect a supplementary inverter or
micro inverter (Max. 4kW).
Zero Export Tick this box to stop exporting power produced by the Aux Load.
Gen Peak Shaving Tick this box to use peak power shaving.
5.22. Advanced Settings for Peak Shaving
To configure Peak Power Shaving function, click on the AUX LOAD icon.icon.
What this page displays:
Generator peak shaving is ON or OFF.
Peak Power Shaving value.
What you can do from this page:
Switch on the generator and/or grid
peak power saving and set the power
shaving value.
Peak Shaving: This is a technique used to reduce electrical power consumption during periods
of maximum demand on the utility grid. This enables the user to save substantial amounts of
money due to the expensive peak power charges.