THREE PHASE HI 8~12kW | Installer Manual65
NOTE:
Micro Inv Input OFF and On is valid for certain FW versions only.
For Micro Inverter Input mode:
Micro Inverter Input: To use the Generator input port as a micro-inverter on grid inverter input (AC
coupled), this feature will also work with "Grid-Tied" inverters. Tick this box if intending to connect a sup-
plementary inverter or micro inverter (Max. 4kW).
AC Couple OFF Batt: When the battery SOC exceeds setting value, Microinveter or the grid-tied inverter
will shut down.
AC Couple ON Batt: If choosing “Micro Inv input”, as the battery SOC reaches a gradually setting value
(OFF), during the process, the microinverter output power will decrease linearly. When the battery SOC
equals to the setting value (OFF), the system frequency will become the setting value (AC couple Frz
high), and the Microinverter will stop working and stop exporting power produced by the microinverter
to the grid.