59
Releasing pressure on a machine equipped with accumulator.
Lower the work equipment on the ground, turn off its breaker or other accessories.
Stop the engine.
Shift starting switch to ON position to flow the circuit current.
Set safety lock lever to free position. Operate work equipment lever and accessory controlpedal forward,
backward, leftward and rightward alternately to release pressure in piping.
Set safety control lever to LOCK position to lock up control lever and accessory pedals.
Power Main Switch
Note
Before starting machine, open power main switch.
After flameout engine,take out key and turn off power main switch.