EasyManua.ls Logo

Supermicro SuperStorage Server 2028R-NR48N - Drive Carrier and Power Supply LED Status

Supermicro SuperStorage Server 2028R-NR48N
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SuperStorage Server 2028R-NR48N
3-4
Overheating
A sensor on the backplane will issue a warning at 45°C. Overheating is critical at
49°C. There are several possible responses if the system overheats.
If the server overheats:
1. Use the LEDs to determine the nature of the overheating condition.
2. Conrm that the chassis covers are installed properly.
3. Check the routing of the cables and make sure all fans are present and operating
normally.
4. Verify that the heatsinks are installed properly.
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive
carrier displays two LED indicators: an activity indicator and a status indicator. The
status indicator functions in RAID congurations. For non-RAID congurations, it
remains off. See the table below for details.
LED Color Blinking Pattern Behavior for Device
Activity LED
Blue Blinking I/O activity
Blue Solid On Idle SAS/NVMe drive installed
Off Off Idle or SATA drive
Status LED
Red Solid On Failure of drive with RSTe
support
Red Blinking at 1 Hz Rebuild drive with RSTe support
Red Blinking with two
blinks and one stop
at 1 Hz
Hot spare for drive with RSTe
support
Red On for ve
seconds, then off
Power on for drive with RSTe
support
Red Blinking at 4 Hz Identify drive with RSTe support
Green Solid On Safe to remove NVMe device
Amber Blinking at 1 Hz Attention state—do not remove
NVMe device

Table of Contents