Bits Per second
Use this feature to set the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and
the client computer. A lower transmission speed may be required for long and
busy lines. The options are 9600, 19200, 57600 and 115200 (bits per second).
Data Bits
Use this feature to set the data transmission size for Console Redirection. The
options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are 1 and 2.
Flow Control
This feature allows the user to set the ow control for Console Redirection to
prevent data loss caused by buffer overow. Send a "Stop" signal to stop send-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are None and Hardware
RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Enabled and Disabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text
messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Dis-
abled and Enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Supermicro X9DRW-iF and is the answer not in the manual?

Supermicro X9DRW-iF Specifications

General IconGeneral
PS/2 ports quantity0
IPMI LAN (RJ-45) portYes
USB 2.0 ports quantity4
Ethernet LAN (RJ-45) ports2
PCI Express slots version3.0
Memory voltage1.35, 1.5 V
Memory channelsDual-channel
Maximum RDIMM memory512 GB
Supported memory typesDDR3-SDRAM
Supported memory clock speeds800, 1066, 1333, 1600 MHz
Maximum UDIMM memory128 GB
Number of DIMM slots16
Supported RDIMM module capacity16GB, 1GB, 2GB, 32GB, 4GB, 8GB
Supported UDIMM module capacity1GB, 2GB, 4GB, 8GB
BIOS typeAMI
ACPI version4.0
BIOS memory size128 Mbit
RAID levels0, 1, 5, 10
Supported storage drive interfacesSATA II, SATA III
Wi-FiNo
LAN controllerIntel® I350
Ethernet interface typeGigabit Ethernet
On-board graphics card modelMatrox G200
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)8 - 90 %
Supported QPI8 GT/s
Processor socketLGA 2011 (Socket R)
Intel Xeon seriesE5-2600
Processor manufacturerIntel
Processor thermal power (max)135 W
Processor number of cores supported6, 8
Component forServer
Motherboard chipsetIntel® C602
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth330 mm
Width305 mm

Related product manuals