16
6. Function&Operation
The following display&operation interfaces are described with kg as the Internal Scale Unit. If the
parameter [P107] Internal Scale Unit is set to ‘g’, the actual Weight Display Unit will be different.
6.1 Main Display Interface
】【 : Display the next/previous interface.
6.1.1 Totalized Weight, Flow & Belt Speed
PressPRINTkey to print: 2009-05-20 23:59
4800000kg
6.1.2 Totalized Weight, Flow & Flow Setpoint
0020.00 [t/h]
R: 0.00-5000.00
P200 Flow Set
Flow[↑↓]: 19.9t/h
Set: 20.0t/h
4800000kg
ENT: Set Flow Setpoint value
: Upper Limit
: Lower Limit
Flow[↑↓]: 19.9t/h
Speed[↑↓]: 0.35m/s
4800000kg