EasyManuals Logo

Supmeter BST100-E81 User Manual

Default Icon
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
26
6.3.4 Extra Control Parameters
No. Parameter Range Default Set
P210 InIHoldTime
0.0-999.9s
PID Initial Current Hold Time
2.0
P211
PID Ini.Cur
(PID Initial Current)
0: Present (Present Current Value)
1: Fuzzy (Fuzzy Current Value)
2: Set [P219] (Set Value of [P219])
0
P212
Fuzzy Equ.
(Fuzzy Equivalent)
0.01~100.00 [t/h]/mA
([P107] Scale Unit = kg)
Flow Increment
per Increasing 1mA Adjusting
Current.
2.50
0.01~100.00 [kg/h]/mA
([P107] Scale Unit = g)
P213
ST/SP Delay
(Start/Stop Delay Time)
0.0~999.9s
Delay Time of Feeder Starting
Delay Time of Scale Stopping
0.0
P214
BatchPermit
(Batch Permission)
0: OFF; 1: ON 0
P215
Batch Loop
(Batch Loop Mode)
0: Manual Mode; 1: Auto Mode 0
P216
Batch Int.
(Batch Interval)
0.0~9999.9s 60.0
P217
Batch Set
(Batch Weight Setpoint)
0~99999999kg
([P107] Scale Unit = kg)
0
0~99999999g
([P107] Scale Unit = g)
P218 BatchPreact
0~[P217] kg
([P107] Scale Unit = kg)
Batch Preact Weight
0
0~[P217] g
([P107] Scale Unit = g)
P219 Set Current
4.00~20.00mA
Set Value of PID Initial Current
12.00
Note:
[P213] Start/Stop Delay:
1. Delay Time of Feeder Starting: When there is a “DI.Start” pulse signal input, DO. Scale Start&Stop Control’ will
turn on to start the belt weigher, and after delaying this time, DO. Feeder Start&Stop Control’ will turn on to start the
feeder.
2. Delay Time of Scale Stopping: When there is a DI.Stoppulse signal input, DO. Feeder Start&Stop Control’ will
turn off to stop the feeder, and after delaying this time, DO. Scale Start&Stop Control’ will turn off to stop the belt
weigher.