6.4.3 Static Span Calibration with Chain Weight
Keep the belt weigher running with loading a chain weight for correcting Span Coefficient.
Put a measured chain weight as a continuous and steady load on the belt weigher and then start the
belt weigher.
05[R]
R: 1-99
P110 Cal. Revs
Main Display Interface
MENU+】【 : F2 Calibration
ENT+】【 3 Span Cal.Stat1
ENT
M
ENT
R: 0.1-1000.0
P111 ChainWeight
010.0[kg/m]
MENU: Exit ENT: Save
ENT
M
NewSpan: 200320
E%: -0.16%
2 Span Cal. Dyn.
OldSpan: 200000
E% = (Display Weight Input Weight) /
Input Weight × 100%