6.1.3 Totalized Weight, Flow & Control Current
6.1.4 Totalized Weight, Load & Load Setpoint
Load=Flow / (3.6×Speed)
Load Setpoint=Flow Setpoint / (3.Speed)
Load: kg/m
Flow: t/h
Belt Speed: m/s
Load[↑↓]: 15.8kg/m
Set: 15.9kg/m
4800000kg
12.26 [mA]
R: 4.00-20.00
Control Current
Flow[↑↓]: 19.9t/h
Ctrl[↑↓]: 12.26mA
4800000kg
ENT: Set Control Current value
ADJ-】【 ADJ+: Control Current ±1mA