EasyManua.ls Logo

Supmeter BST100-E81 - F1 Setting; Basic Scale Parameters

Default Icon
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
6.3 F1 Setting
6.3.1 Basic Scale Parameters
No. Parameter Range Default Set
P100
DispalyUnit
(Weight Display Unit)
0: kg
1: t
([P107] Scale Unit = kg)
0
0: g
1: kg
([P107] Scale Unit = g)
P101
Decimal
(Weight Decimal Point)
0: o
1: o.o
2: o.oo
When [P100]=1, its valid.
1
P102 Belt Length 0.01~5000.00m
10.00
[*]
P103
SpeedCoeff.
(Speed Coefficient)
1.0~99999.9pl/m (pulse/m)
100.0
[*]
P104 Zero Value 0~60000 (AD Value)
15000
[*]
P105
Span Coeff.
(Span Coefficient)
1~99999999
200000
[*]
P106
SL Deadband
(Weighing Daedband)
±(0.00~200.00) t/h
([P107] Scale Unit = kg)
If Flow < Deadband value, the variance of
Totalized Weight will be ignored.
±0.00
±(0.00~200.00) kg/h
([P107] Scale Unit = g)
P107
Scale Unit
(Internal Scale Unit)
0: kg
1: g
0/1
[*]
[*]: ‘RAM Reset operation has no effect on this parameter.