3. Features
3.1. Alarms, warnings and notifications
Suunto D5 has color-coded alarms, warnings and notifications. They are shown prominently
on the display with an audible alarm (if tones are on). Alarms are always red. Warnings may be
red or yellow.
Notifications are always yellow.
Suunto D5 has vibration alarm. The vibration can be turned on or o for dive alarms,
notifications and warnings.
Alarms are critical events that always require immediate action. When an alarm situation
comes back to normal, the alarm will stop automatically.
Alarm
Explanation
Ascent speed exceeds safe speed of 10 m (33 ft) per
minute for five seconds or more.
Decompression ceiling broken by more than 0.6 m (2 ft)
on a decompression dive. Immediately descend back
below ceiling depth and continue to ascend normally.
Partial pressure of oxygen exceeds safe level (>1.6).
Immediately ascend or change to a gas with lower
oxygen percentage.
Warnings alert you to events that can impact your health and safety if you do not take action.
Acknowledge the warning by pressing any button.
Warning
Explanation
CNS 100% Central nervous system toxicity level at 100% limit
OTU 300 Recommended daily limit for Oxygen tolerance unit
reached
Depth Depth exceeds your depth alarm limit
Dive time Dive time exceeds your dive time alarm limit