84 RV125K7 (’07-MODEL)
• Remove the inlet tube filter 4.
• Remove the fuel level switch 5.
INSPECTION
Inlet tube filter
• Inspect the inlet tube filter for clogging or any damage.
• If necessary, clean the inlet tube filter using compressed air.
Fuel level switch
• Connect a 12 V battery and bulb (12 V 3.4 W) to the fuel level
switch as shown. It is possible that the bulb comes on in 20 –
30 sec. after the connection.
• Immerse the fuel level switch into kerosen 1 and make sure
that the bulb goes off. If not, replace the fuel level switch with
a new one.
B/W
Y/B
Y/B
B/W