6-8 EXHAUST SYSTEM
• Connect the EXCV cables (No.1 and No.2) temporarily to the
EXCV pulley.
• Make the No. 1 cable (21H0CL) straight and turn the No. 1
cable adjuster in or out until the inner cable length "
becomes 44 – 45 mm (1.73 – 1.77 in).
• After adjusting the inner cable length ", tighten the lock-nut
.
• Make the No. 2 cable (21H0OP) straight and turn in the
cable adjuster fully.
• Loosen the lock-nuts and turn the No.2 cable adjuster in
or out until the inner cable length # becomes 60 – 61 mm
(2.36 – 2.40 in).
• After adjusting the inner cable length #, tighten the lock-nuts
.
• Connect the No. 1 cable and No. 2 cable to the EXCVA
pulley. (6-6)
• Install the EXCVA. (6-6)
• After connecting the No. 2 cable , loosen the lock-nut
and turn the adjuster in or out until 11 – 12 mm (0.43 – 0.47
in) of the thread length $ on the cable adjuster can be pro-
vided and tighten the lock-nut .
The cable slots of EXCVA pulley must be located
adjustment position. (6-4)