PERIODIC MAINTENANCE 2-19
AIR BLEEDING THE COOLING CIRCUIT
• Add engine coolant up to the radiator inlet.
• Support the motorcycle upright.
• Slowly swing the motorcycle, right and left, to bleed the air
trapped in the cooling circuit.
• Add engine coolant up to the radiator inlet.
• Start up the engine and bleed air from the radiator inlet com-
pletely.
• Add engine coolant up to the radiator inlet.
• Repeat the above procedure until no air bleeds from the radi-
ator inlet.
• Lift and support the fuel tank. (5-3)
• Loosen the air bleeder bolt and check that the engine cool-
ant flows out.
• Tighten the air bleeder bolt securely.
• Close the radiator cap securely.
• After warming up and cooling down the engine several times,
add the engine coolant up to the full level of the reservoir.
Engine coolant capacity:
Engine side : 2 250 ml (2.4/2.0 US/Imp qt)
Reservoir tank side : 250 ml (0.3/0.2 US/lmp qt)
Repeat the above procedure several times and make
sure that the radiator is filled with engine coolant up to
the reservoir full level.