Electrical systems
64
3.4 Common Fault Table
Fault Possible Cause Proposed Fix
No 230 volt output from PSU
Connecting lead between
the site and Leisure
Vehicle not connected
as per 2.3C
RCD switched off Reset RCD
RCD not operating
correctly
Check supply polarity; if the RCD continues to fail contact
your Dealer as there is probably an equipment or wiring
fault.
MCB switched off
Reset MCB by switching OFF (down position) then back
ON (up position), if the MCB continues to fail contact your
Dealer as there is probably an equipment or wiring fault.
No or deficient supply
from site
Contact site Warden for assistance
Other fault Contact your Dealer
Reverse Polarity light is
illuminated on PSU
Mains Supply reversed?
The reverse polarity light is designed to illuminate when the Live and Neutral
supply has been reversed / crossed over. If the light illuminates there is a problem
with the site supply or the cable connecting the supply to your vehicle. The light
is designed to work on UK electrical supplies (where the neutral conductor is
connected to earth at the sub station). If you are using your vehicle outside the
UK this light may illuminate when no fault exists. In these cases consult the site
warden for advise.
Generator being used
‘The Reverse Polarity warning light is on when using my Generator’.
This is a normal side effect when using some types of generator.
Instead of connecting the neutral conductor to earth, some generators centre tap
the earth connection making both neutral and live conductors 110v above earth.
This 110v difference causes the neon polarity indicator to illuminate. In most cases
it is still safe to use the generator, but please consult the generator handbook for
further information.