Sylvac Scan Series - 1.7 SYLVAC-Scan 50 CE Plus Specifications

Sylvac Scan Series
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 - 36
1.7 SYLVAC-Scan 50CE Plus specifications
DIMENSIONS
Imperial
Measuring center (HxWxD)
41 x 32 x 23 in
Computer mini tower
-
WEIGHT
Measuring center
272 lbs
Complete System including PC
320 lbs
OPERATIONAL REQUIREMENTS
Storage Temp. Range
-22 to 140°F
Storage Humidity
75% rh max.
Operating Temp. Range
50 to 95°F
Operating Humidity
10 to 80% rh
Power Requirement
Power Consumption
PERFORMANCE (at 20°C)
RESOLUTION
Lengths
0.00004 in
Diameters
0.00001 in
REPEATABILITY (±2 σ = 95%)
Lengths
±0.00008 in
Diameters
±0.00002 in
ACCURACY
(Error of mean measured value)
Lengths
(0.16+0.01 L)/1000 in
Diameter
(0.04+0.01 D)/1000 in
CAPACITY
Component Capacity
Ø 3.9 in x L 11.4 in
Measurement Capacity
Ø 1.96 in x L 10.8 in
Component Weight
13.2 lbs
SPEED
(static measurement)
Diameter
Edge
Typical Cycle Time (10 features)
Noise level
Performance data is based on results from clean ground components at 20°C and may be affected by
component shape and surface.

Table of Contents