64
Electronic control system
t1
Start of the flashing light before the automatic wrapping cycle starts.
It is recommended to mount a flashing light when a remote control is
mounted.
t2
The time can be set before an error message occurs, in case a sensor
does not function.
t3
This setting is only valid in case your machine is equipped with the
electronic control system.
The maximum raising time for the loading arm from the middle position
to the fully lifted position.
t4
This setting is only valid in case your machine is equipped with the
electronic control system.
The time delay for lowering the loading arm after reaching the sensor.
t5
Before the table rotates at normal speed, a slow-motion start time can
be set.
t6
After the last sensor by-pass, the table speed can be delayed slow
down.
Flashing light Setting Recommended setting
mounted
not mounted
sec and 1/10 sec
sec and 1/10 sec
2.0
0.0
Setting Recommended setting
sec 15
Setting Recommended setting
sec 4 - 6
Setting Recommended setting
sec and 1/10 sec 0.5
Setting Recommended setting
sec and 1/10 sec 2.5
Setting Recommended setting
sec and 1/10 sec 1.0 - 2.0