The DEBUG Utility
WRITE
W [address[drive sector sectorcountJJ
Writes
the
data
being debugged to a disk file.
Parameters
address is
the
memory location of
the
data
to be saved.
drive sector designates
the
disk drive to be used
for
the
save.
sector designates
the
starting
diskette sector
for
the save.
sectorcount indicates
the
number of sectors to be used
in
the
save.
Notes
If
no
parameters
~re
given,
the
file save begins
at
CS:I00.
If
only
the
address
parameter
is given,
the
W command writes
the file
beginning
at
that
address.
In
either case, you
must
be
certain
that
BX:CX contains
the
number of bytes to write.
This value may have been
set
correctly
by
the DEBUG or Load
commands,
but
later
altered
by a
Go
or Trace command. (Note
that
if
you load
and
modify a file,
the
name, length,
and
start-
ing address
are
already
set
correctly as long
as
the
length has
not changed.)
The file
must
have been named either
with
the
DEBUG
start-
up command or
with
the
Name command. Both commands
for-
mat
a filespec properly
in
the
File Control Block
at
CS:5C.
DEBUG
writes
the
file to
the
drive specified
in
the
filespec or
to
the
default drive
if
none is specified.
290
I )
i
I..-!
, I
! :
, I
~
i '
I I
!
-..J
i f
, I
'--..J
I l
~
!
, I
-....-l
I '
\ '
L..-.
: '
i ,
I I
~

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tandy 1000 MS-DOS and is the answer not in the manual?

Tandy 1000 MS-DOS Specifications

General IconGeneral
BrandTandy
Model1000 MS-DOS
CategoryDesktop
LanguageEnglish

Related product manuals