6-6
OPERATING PROCEDURES
Model C708 - WAWA
Operating Procedures
6
3. Assemble the liquid valve body. Slide the three check
rings and three O-rings into the grooves on the liquid
valve body. Do not lubricate the check rings or
O-rings. (See Figure 6-21.)
Figure 6-21
Note: Check rings have two smooth surfaces. A
concave shape indicates an incorrect assembly. Turn the
check ring inside out to correctly expose the flat surface.
(
See Figure 6-22.)
Figure 6-22
4. Put a small amount of lubricant on the inside
diameter of the piston. Insert the narrow end of the
liquid valve body into the open end of the piston.
Once applied, the amount of lubricant should be
equal to a paper-thin film. (
See Figure 6-23.)
Figure 6-23
5. Apply a small amount of lubricant to the lower inside
diameter of the pump cylinder to a depth equivalent
to the length of your index finger. Once applied, the
amount of lubricant should be equal to a paper-thin
film. (
See Figure 6-24.)
Figure 6-24
15010
15041
15119
Apply the appropriate
Taylor approved food safe lubricant.
HP
15003
Apply the appropriate
Taylor approved food safe lubricant.
HP