EasyManua.ls Logo

TCL TCA-60HRA/DV3O - The Specification of Power; Installation Requirements of Indoor Unit; Installation Space

TCL TCA-60HRA/DV3O
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC Inverter Air
7. Owner's manual
1
Others
8. Installation manual
1
9. Remote controller manual
1
3.6 The S pecification of Pow er
MOD EL
TCA‐18ZHR A/DV
TCA‐24ZHRA/D V3
INDOOR
PHASE
1‐PHASE
1‐PHASE
UNIT
FREQ UENCY AND V OLT
220‐240V
0Hz
220‐240V 50Hz
POWER
POWER WIRING (M M
2
)
3*2.5
3*2.5
CIRC UIT BREAKER (A)
15
15
OUTDOOR
PHASE
1‐PHASE
3‐ PHASE
UNIT
FREQ UENCY AND V OLT
220‐240V
0Hz
380V 50Hz
POWER
POWER WIRING (M M
2
)
3*4.0
4*4.0
CIRC UIT BREAKER (A)
30
30
INDO OR/OUTDOO R CONNECTION
3*0.75
3*0.75
WIRING(WEAK ELECT RIC SIGNAL((MM
2
)
INDO OR/OUTDOO R CONNECTION
3*2.5
3*2.5
WIRING( STRANG ELECTRIC SIGNAL (MM
2
)
MOD EL
TCA‐36ZHR A/DV
TCA‐48ZHRA/D V3
TCA‐60ZHRA/DV3
INDOOR
PHASE
1‐PHASE
1‐PHASE
1 ‐PHASE
UNIT
FREQ UENCY AND V OLT
220‐240V
0Hz
220‐240V 50Hz
220‐240V 50Hz
POWER
POWER WIRING (M M
2
)
3*2.5
3*2.5
3*2.5
CIRC UIT BREAKER (A)
15
15
15
OUTDOOR
PHASE
1‐PHASE
3‐ PHASE
3‐ PHASE
UNIT
FREQ UENCY AND V OLT
220‐240V
0Hz
380V 50Hz
38 0V 50Hz
POWER
POWER WIRING (M M
2
)
3*4.0
4*4.0
4*4.0
CIRC UIT BREAKER (A)
30
30
30
INDO OR/OUTDOO R CONNECTION
3*0.75
3*0.75
3*0.75
WIRING(WEAK ELECT RIC SIGNAL((MM
2
)
INDO OR/OUTDOO R CONNECTION
3*2.5
3*2.5
3*2.5
WIRING( STRANG ELECTRIC SIGNAL (MM
2
)
3.7 Installation Requirements of Indoor Unit
1) Installation Space
Floor console
45/ 113

Table of Contents