Product Name: UNIVOLT N 61 B
Revision Date: 16 Mar 2015
Page 7 of 11
______________________________________________________________________________________________________________________
STABILITY: Material is stable under normal conditions.
CONDITIONS TO AVOID: Excessive heat. High energy sources of ignition.
MATERIALS TO AVOID: Strong oxidizers
HAZARDOUS DECOMPOSITION PRODUCTS: Material does not decompose at ambient temperatures.
POSSIBILITY OF HAZARDOUS REACTIONS: Hazardous polymerization will not occur.
SECTION 11
TOXICOLOGICAL INFORMATION
INFORMATION ON TOXICOLOGICAL EFFECTS
Hazard Class
Conclusion / Remarks
Inhalation
Acute Toxicity: No end point data for
material.
Minimally Toxic. Based on assessment of the components.
Irritation: No end point data for material.
Elevated temperatures or mechanical action may form vapors,
mist, or fumes which may be irritating to the eyes, nose, throat, or
lungs.
Ingestion
Acute Toxicity: No end point data for
material.
Minimally Toxic. Based on assessment of the components.
Skin
Acute Toxicity: No end point data for
material.
Minimally Toxic. Based on assessment of the components.
Skin Corrosion/Irritation: No end point data
for material.
May dry the skin leading to discomfort and dermatitis. Based on
assessment of the components.
Eye
Serious Eye Damage/Irritation: No end point
data for material.
May cause mild, short-lasting discomfort to eyes. Based on
assessment of the components.
Sensitization
Respiratory Sensitization: No end point data
for material.
Not expected to be a respiratory sensitizer.
Skin Sensitization: No end point data for
material.
Not expected to be a skin sensitizer. Based on assessment of the
components.
Aspiration: Data available.
May be fatal if swallowed and enters airways. Based on
physico-chemical properties of the material.
Germ Cell Mutagenicity: No end point data
for material.
Not expected to be a germ cell mutagen. Based on assessment of
the components.
Carcinogenicity: No end point data for
material.
Not expected to cause cancer. Based on assessment of the
components.
Reproductive Toxicity: No end point data
for material.
Not expected to be a reproductive toxicant. Based on assessment
of the components.
Lactation: No end point data for material.
Not expected to cause harm to breast-fed children.
Specific Target Organ Toxicity (STOT)
Single Exposure: No end point data for
material.
Not expected to cause organ damage from a single exposure.
Repeated Exposure: No end point data for
material.
Not expected to cause organ damage from prolonged or repeated
exposure. Based on assessment of the components.