32
[PROGram]:WAVE:TIME
Parameter Each value is loaded into a pair of registers. Low address value holds the least
significant part. Refer to Section 9.9 for an example of List Dwell registers.
Upload [PROGram]:WAVE:TIME registers
Specific MODBUS TCP specific command used to upload [PROGram]:WAVE:TIME into
power supply. Refer to Section 9.9 for an example of List Dwell registers.
[PROGram]:WAVE:VOLTage
Parameter Each value is loaded into a single register. Refer to Section 9.9 for an example
of List Voltage registers.
Upload [PROGram]:WAVE:VOLTage registers
Specific MODBUS TCP specific command used to upload [PROGram]:LIST:VOLTage into
power supply. Refer to Section 9.9 for an example List Dwell registers.
Number of the points
Parameter MODBUS TCP specific command used to set the number of points of a sequence
to load into a power supply. Refer to Section 9.9 for an example.
[SOURce]:VOLTage:PROTection:LOW:DELay
Unit 100mSec. Multiply register value by 100mSec. For example: 1 equals 100mec;
5 equals 500mSec.
[SOURce]:CURRent:SLEW:DOWN
Parameter Each value is loaded into a pair of registers. Low address value holds the least
significant part.
[SOURce]:CURRent:SLEW:UP
Parameter Each value is loaded into a pair of registers. Low address value holds the least
significant part.
[SOURce]:VOLTage:SLEW:DOWN
Parameter Each value is loaded into a pair of registers. Low address value holds the least
significant part.
[SOURce]:VOLTage:SLEW:UP
Parameter Each value is loaded into a pair of registers. Low address value holds the least
significant part.
[SOURce]:VOLTage:MODE
Parameter
NONE - 0x0000; LIST - 0x0001; WAVE - 0x0002 as return value.