- 147 -
EO3-11070
MA-1650-4 SERIES
ERROR MESSAGE PROGRAMMING (Submode 32)
The messages to be set programmed here will be displayed when errors occur. Each error will be indicated with
an error tone, and the Error Message (to be set here) is displayed in maximum 16 characters.
CONDITION Any time outside a sale
OPERATION Mode Lock: SET
32 [X] |Error Code| [ST] Character Entries [ST] [AT/TL]
Indicates the end of each error
message (any unprogrammed
parts will be filled with blanks).
........
Repeat for another error code.
➤
➤
➤
➤
➤
➤
(See the table on the
next page.)
*
* (For sequentially programming
messages, the error code
specification can be skipped.)
TEC STORE
1343 PEACH DRIVE
PHONE: 87-6437
Open 8:00am to 7:00pm
Closed: every Wednesday
11-14-1994 MON #1
P32
17 MASTER BUSY
0063
NOTES: 1. A maximum of 16 characters can be programmed for each error message. Enter all the
characters in regular size.
2. As shown in the table on the next page, the Standard Program data are prepared (which is auto-
set after a RAM Clear). Therefore, program only the error messages that need to be changed.
ex.) To change the following items:
ERROR CODE STANDARD DATA CHANGE
17 MASTER IS BUSY MASTER BUSY
Mode Lock to SET, 32 [X]
17 [ST] (Error Code)
413 [#] (M)
401 [#] (A)
503 [#] (S)
504 [#] (T)
405 [#] (E)
502 [#] (R)
[#] (space)
402 [#] (B)
505 [#] (U)
503 [#] (S)
509 [#] (Y)
[ST] (to complete Code 17) [AT/TL]