- 27 -
EO3-11070
MA-1650-4 SERIES
Function Keys
Except for the [CODE] key, each of the function keys corresponds to the identical key installed on the ECR
keyboard as to the function in programming operations. ([CLEAR] = [C], [X] = [@/FOR])
The [CODE] key cannot be used for the MA-1650 series ECRs.
Operation Examples
To set the Menu Item name “COFFEE” for Dept. 2:
ON ECR KEYBOARD ONLY
3 [#] [DEPT 2] 2 [#] 403 [#] 415 [#] 406 [#] 405 [#] 405 [#] 405 [#] [ST]
COFFEE
[AT/TL]
USING TKB-1 KEYBOARD
3 [X] [DEPT 2] 2 [ST] C O F F E E [ST] [AT/TL]
on ECR
on TKB-1 on ECR or TKB-1
The “One Double-size Declaration” (by depression [X] once prior to the required character) and the “All
Double-size Declaration” (by depressing [X] twice before the entire descriptor) are the same as in setting
characters on the ECR keyboard.
Any characters not listed on the TKB-1 keyboard may be entered by the code entry method on the ECR
keyboard.