ADDRESS No. CONTENTS
BIT ITEM SELECTIVE STATUS
STANDARD
REMARKS
No.
STATUS
SYSTEM OPTION TABLE
- 49 -
EO3-11070
MA-1650-4 SERIES
Standard Bit Set (auto-set by RAM Clear)
➤
RESET
SET
RESET
SET
RESET
SET
RESET
SET
RESET
SET
RESET
SET
RESET
SET
RESET
SET
1
2
3
4
5
6
7
8
0
8 SCANNING OPTION I
Conversion of Shortened
Type UPC-E of Barcodes
-- vacant --
-- vacant --
-- vacant --
-- vacant --
-- vacant --
-- vacant --
-- vacant --
Padding preceding digits with 0 *
Converted to a 13-digit code
*
*
*
*
*
*
*
NOTE below
NOTE 1: This status selection is applied to the Read Code Nos. 2 and 11 (refer to the SCANNING SPECIFICATIONS in the SYSTEM
EXPLANATION manual), and determines the way to convert the shortened code into a 13-digit code.
Read Code No. 2 RESET (padding preceding digits with 0):
Shortened Code = X
1
X
2
X
3
X
4
X
5
X
6
→
Converted = 0 0 0 0 0 0 0 X
1
X
2
X
3
X
4
X
5
X
6
SET (Converted to a 13 digit code)
When X
6
= 5 to 9: 0 0 0 X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
When X
6
= 4: 0 0 0 X
1
X
2
X
3
X
4
0 0 0 0 0 X
5
When X
6
= 3: 0 0 0 X
1
X
2
X
3
0 0 0 0 0 X
4
X
5
When X
6
= 0 to 2: 0 0 0 X
1
X
2
X
6
0 0 0 0 X
3
X
4
X
5
Read Code No. 11 RESET (padding preceding digits with 0):
Shortened Code = X
1
X
2
X
3
X
4
X
5
X
6
→
Converted = 0 0 0 0 0 0 0 X
1
X
2
X
3
X
4
X
5
X
6
SET (Converted to a 13 digit code)
0 0 0 X
1
X
2
X
3
X
4
X
5
0 0 0 0 X
6
-- Address Nos. 9 and 10 are vacant. --