5. INSTALLATION INSTRUCTIONS
5.1. SPECIFICATIONS AND REQUIREMENTS
For correct machine installation, make sure that:
1. The machine is installed on a level surface that is free of vibrations and has sufficient carrying
capacity for the combined weight of the machine and user;
2. The place of installation is free of dust and sand;
3. The place of installation meets the operating temperature and humidity conditions specified in
paragraph: 2.7. “Ambient specifications”;
4. The machine is not positioned close to sources of heat, sources of electromagnetic noise
(television sets, electrical motors, antennas, high voltage lines, household appliances, etc...) or
medical equipment;
5. Each machine must have a dedicated power supply line;
6. The socket outlet and other devices on the dedicated line should be appropriately sized for the
required load 16A;
7. The socket outlets must be earthed;
8. No multiple connections are permitted on the ground and/or the neutral cables;
9. The ratio between the length and cross section ratio of the cables must be sufficient to assure a
maximum voltage drop of 4% of nominal value at full load at the socket outlet;
10. Position the mains lead of the machine where it will not be underfoot;
11. To eliminate any interference with the cardio receiver, no transmitters should be placed less than
90 cm from the display.
12. There is plenty of free space around each item of equipment and a free space of 2x1 min front of
the machine as shown in the picture: