RUN PERSONAL: Service & maintenance manual - rev. 3.1
Page 6.13
19/EM
EMERGENCY. Is generated when low kit
drive receives a software emergency signal
that is not accompanied by a hardware
-
20/SFAn
LOW KIT DRIVER COVER PLATE FAN.
This error is genereted if there is a
mulfunction on the fan mounted on the
driver’s cover plate, for at least 5 sec.
• low kit driver cover plate fan
21/PFAn
LOW KIT DRIVER INTERNAL FAN. This
error is genereted if there is a mulfunction on
the internal low kit driver fan, for at least 5
• low kit driver internal fan
22/IMV
INVERTER POWER SUPPLY: This error is
generated if a voltage <156 VAC for at least
1 sec. when the AC motor is working or for
at least 10 sec. when AC motor is not
-
23/SHC
SHORT CIRCUIT. Is generated in the event
of a short circuit between a motor phase and
• Check the belt motor
24/OHS
OVERHEATING of the dissipator sensor:
This error is genereted if a mulfunction of
the dissipator sensor last more than 1 sec.
• low kit driver