TD350 Series VFD Basic operation instructions
-79-
Function
code
Name
Detailed parameter description
Default
value
2: PROFIBUS / CANopen /DeviceNet
3: Ethernet communication
4: EtherCAT/PROFINET/Ethernet IP
communication
Tens: Enable switching during operation
0: Disable
1: Enable
P12.00
Type of motor 2
0: Asynchronous motor
1: Synchronous motor
0
P12.01
Rated power of
asynchronous motor 2
0.13000.0kW
Depend
on model
P12.02
Rated frequency of
asynchronous motor 2
0.01HzP00.03 (Max. output frequency)
60.00Hz
P12.03
Rated speed of
asynchronous motor 2
136000rpm
Depend
on model
P12.04
Rated voltage of
asynchronous motor 2
01200V
P12.05
Rated current of
asynchronous motor 2
0.86000.0A
P12.06
Stator resistance of
asynchronous motor 2
0.001–65.53
P12.07
Rotor resistance of
asynchronous motor 2
0.001–65.53
P12.08
Leakage inductance of
asynchronous motor 2
0.16553.5mH
P12.09
Mutual inductance of
asynchronous motor 2
0.16553.5mH
P12.10
No-load current of
asynchronous motor 2
0.16553.5A
P12.15
Rated power of synchronous
motor 2
0.13000.0kW
P12.16
Rated frequency of
synchronous motor 2
0.01HzP00.03 (Max. output frequency)
60.00Hz
P12.17
Number of pole pairs of
synchronous motor 2
150
2
P12.18
Rated voltage of
synchronous motor 2
01200V
Depend
on model

Table of Contents