AFMS N°D03 FOR ALTERNATIVE AVIONICS CONFIGURATION
Page 3G-5
Section 3 Emergency procedures
AVIONIC SUITE FAILURES
Ed. 1, Rev.0
2. FAILURES INDICATED ON THE ANNUNCIATION PANEL
The annunciator panel, located on the centre of the instrument panel, contains 9
lights for warnings, cautions and advisories. The colours are as follows:
GREEN: to indicate that pertinent device is turned ON
AMBER: to indicate no-hazard situations which have to be considered and
which require a proper crew action
RED: to indicate emergency conditions
WHITE: to indicate advisory messages
2.1 ALTERNATOR FAILURE
If ALT FAIL caution is ON:
1. Circuit breaker(s)……………………...
Check
2. Generator SWITCH………………...…
OFF
3. Generator SWITCH…………………...
ON
If ALT FAIL CAUTION REMAINS on:
4. Generator SWITCH………………...…
OFF
A fully charged battery shall supply electrical power for at least 30
minutes.