4-119
06-- Automatic program operation function group
06- 00
Automatic operation mode selection
Range
0:
Invalid
1:
Execute a single cycle operation mode. Restart speed is based on the previous
stopped speed.
2:
Execute continuous cycle operation mode. Restart speed is based on the previous
stopped speed.
3:
After the completetion of a single cycle, the on-going operation speed is based on the
speed of the last stage. Restart speed is based on the previous stopped speed
4: Execute a single cycle operation mode. Restart speed will be based on the speed
of stage 1
.
5: Execute a single cycle operation mode. Restart speed will be based on the speed
of stage 1
6:
After the completetion of a single cycle, the on-going operation speed is based on the
speed of the last stage. Restart speed is based on the previous stopped speed.
The frequency of multi-step speed 0 is set by 05-01
06- 01 Frequency setting of speed-stage 1
06- 02 Frequency setting of speed-stage 2
06- 03 Frequency setting of speed-stage 3
06- 04 Frequency setting of speed-stage 4
06- 05 Frequency setting of speed-stage 5
06- 06 Frequency setting of speed-stage 6
06- 07 Frequency setting of speed-stage 7
06- 08 Frequency setting of speed-stage 8
06- 09 Frequency setting of speed-stage 9
06- 10 Frequency setting of speed-stage 10
06- 11 Frequency setting of speed-stage 11
06- 12 Frequency setting of speed-stage 12
06- 13 Frequency setting of speed-stage 13
06- 14 Frequency setting of speed-stage 14
06- 15 Frequency setting of speed-stage 15
Range
0.00~400.00Hz
0.0~1200.0Hz ( when 00-31 = 1)
06- 16 Operation time setting of speed-stage 0
06- 17 Operation time setting of speed-stage 1
06- 18 Operation time setting of speed-stage 2
06- 19 Operation time setting of speed-stage 3
06- 20 Operation time setting of speed-stage 4
06- 21 Operation time setting of speed-stage 5
06- 22 Operation time setting of speed-stage 6
06- 23 Operation time setting of speed-stage 7
06- 24 Operation time setting of speed-stage 8
06- 25 Operation time setting of speed-stage 9
06- 26 Operation time setting of speed-stage 10
06- 27 Operation time setting of speed-stage 11
06- 28 Operation time setting of speed-stage 12
06- 29
Operation time setting of speed-stage 13

Table of Contents