4-19
Group 04 External terminal analog signal input(output) function group
Control mode
Code Parameter Name Range Default Unit
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
Attrib
ute
0: AI1:0~10V AI2: 0~10V
1: AI1:0~10V AI2: 4~20mA
2: AI1: -10~10V AI2: 0~10V
04-00
A
I input signal type
3: AI1: -10~10V AI2: 4~20mA
1 - O O O O O O
04-01
A
I1 signal scanning and
filtering time
0.00~2.00 0.03 s O O O O O O
04-02
A
I1gain value 0.0~1000.0 100.0 % O O O O O O *1
04-03
A
I1bias voltage value -100.0~100.0 0 % O O O O O O *1
04-04 Retain
0: Auxiliary Frequency
1: Frequency Reference Gain
2: Frequency Reference Bias
3: Output Voltage Bias
4: Coefficient of acceleration
and deceleration reduction
5: DC braking current
6: Over-torque detection level
7: Stall prevention Level During
Running
8:Frequency lower limit
9:Jump frequency 4
10: Added to AI1
11: Positive torque limit
12: Negative torque limit
13: Regenerative Torque Limit
14: Positive / negative torque
limit
15: Torque Reference/Torque
Limit (in speed control)
16: Torque compensation
04-05
A
I2 function setting
17: No function
10 - O O O O O O
04-06
A
I2 signal scanning and
filtering time
0.00~2.00 0.03 s O O O O O O
04-07
A
I2 gain value 0.0~1000.0 100.0 % O O O O O O *1
04-08
A
I2 bias voltage value -100.0~100.0 0 % O O O O O O *1
04-09 Retain
04-10 Retain
0: Output frequency
1: Frequency command
2: Output voltage
3: DC voltage
4: Output current
5: Output power
6: Motor Speed
7: Output power factor
04-11
A
O1 function setting
8: AI1 input
0 - O O O O O O

Table of Contents