4-45 
 
Group 17 Automatic Tuning Function Group 
Control mode 
Code  Parameter Name  Range  Default Unit
V/F 
V/F 
+PG 
SLV SV 
PM
SV
PM
SLV
Attrib
ute
0: rotation autotune 
1: static autotune 
17-00 
Mode selection of 
automatic tunning 
2: stator resistance 
measurement 
0  -  O O O O X X  
17-01 
Motor rated output 
power
 
0.00~600.00  -  KW O O O O X X  
17-02  Motor rated current  0.1~999.9  -  A O O O O X X  
200V: 0.0~255.0  220
17-03  Motor rated voltage 
400V:0.0~510.0 440
V O O O O X X  
17-04  Motor rated frequency 
10.0~400.0  
10.0~1200.0 (when 00-31 = 1)
60.0 Hz O O O O X X  
17-05  Motor rated speed  0~24000  1750 rpm O  O  O  O  X X  
17-06  Pole number of motor  2,4,6,8  4  Pole O  O  O  O  X X  
17-07  Number of PG pulse  0~60000  1024 ppr X O  X  O  X X  
200V: 50~240 
17-08  Motor no-load voltage 
400V100~480 
-  V O O O O X X  
17-09 
motor excitation 
current  
0.01~600.00   -  A O O O O X X  
0: invalid 
17-10 
utomatic tuning start 
1: valid 
0  -  O O O O X X  
0: No error 
1: Motor data error 
2: stator resistance tuning 
error 
3:leakage induction tuning 
error 
4: Rotor resistance tuning 
error 
5: mutual induction tuning 
error 
6: encoder error 
7: DT Error 
8: Motor’s acceleration error 
17-11 
Error history of 
automatic tuning 
9: Warning 
0  -  O O O O X X