3-16
3.15 General Specification
Item
L510
Control Mode
V/F Control + SLV Control
Frequency
Range
0.01~599.00Hz
Setting resolution
Digital input : 0.01Hz
Analog input : 0.06Hz/60Hz
Setting
Keypad : Set directly with▲▼ keys or use VR (Potentiometer) on the
keypad
External Input Terminals:
AVI(0/2~10V), ACI(0/4~20mA)input
Multifunction input up/down function(Group3)
Setting frequency by Communication method.
Frequency limit
Lower and upper frequency limits
3 -skip frequency settings.
Run
Operation set
Keypad run, stop button
External terminals:
Multi- operation-mode 2 / 3 wire selection
Jog operation
Run signal by communication method.
Main Controls
V / F curve setting
6 fixed curve and one customized curve
Carrier frequency
1~16KHz(default 5KHz)
Acceleration and
deceleration control
2 Acc / dec time parameters.
4 S curve parameters.
Multifunction input
19 functions (refer to description in group 3)
Multifunction output
14 functions (refer to description in group 3)
Multifunction analog
output
5 functions (refer to description in group 4)
1 Output (0-10V)
Main features
Overload Detection, 8 preset speeds, Auto-run, Acc/Dec Switch (2
Stages), Main/Alt run Command select, Main/Alt Frequency
Command select, PID control, torque boost, V/F start
Frequency ,Fault reset.
Display
LED
Display: parameter/parameter value/frequency/line speed/DC
voltage/output voltage/output current/PID feedback/input and output
terminal status/Heat sink temperature/Program Version/Fault Log.
LED Status Indicator
For run/stop/forward and reverse.