Group 02: Motor Parameters
SLV Slip
Compensation Gain
SLV Torque Compensation Gain
Low Frequency Torque Gain
SLV Without Load Slip
Compensation Gain
SLV With Load Slip Compensation
Gain
Group 03: External Digital Input and Output Parameters
Multi-function Terminal Function
Setting-S1
0: Forward/Stop Command or Run /Stop
1: Reverse/Stop Command Or REV/FWD
2: Preset Speed 1 (5-02)
3: Preset Speed 2 (5-03)
4: Preset Speed 4 (5-05)
6: Jog Forward Command
7: Jog Reverse Command
8: Up Command
9: Down Command
10: Acc/Dec 2
11: Acc/Dec Disabled
12: Main/Alternative Run Command select
13: Main/Alternative Frequency Command select
14: Rapid Stop ( Decel to stop)
15: Base Block
16: Disable PID Function
17: Reset
18: Auto Run Mode enable
Multi-function Terminal Function
Setting-S2
Multi-function Terminal Function
Setting-S3
Multi-function Terminal Function
Setting-S4
Multi-function Terminal Function
Setting-S5
0: When Up/Down is used, the preset frequency
is held as the inverter stops, and the UP/Down
function is disabled.
1: When Up/Down is used, the preset frequency
is reset to 0 Hz as the inverter stops.
2: When Up/Down is used, the preset frequency
is held as the inverter stops, and the UP/Down is
available.
1~200. Number of Scan cycles
2:Setting Frequency Reached
3:Frequency Reached (3-13±3-14)
4:Output Frequency Detection1(> 3-13)
5:Output Frequency Detection2(< 3-13)