EasyManua.ls Logo

TECO L510S Series - Page 178

TECO L510S Series
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
App 3-6
Register
No.
Contents
2521H
abnormity
00 The inverter is normal 25 Inverter over heat during running(OH-C)
01 Inverter over heat(OH) 26 Stop at 0 speed(STP0)
02 Over current at stop(OC) 27 Direct start malfunction(STP1)
03 Under voltage(LV) 28 Control panel emergency stop(STP2)
04 Over voltage(OV) 29 Keypad operation error)(Err1)
05 Reserved 30 Parameter setting error(Err2)
06 External BB(bb) 31 Analog transferred error(Err4)
07 CPU error by external signal(CTE ) 32
Parameter changed during Communication
(Err5)
08 PID feedback signal lost(PDER) 33 Communication failure(Err6) (Note)
09 EEPROM abnormal(EPR) 34 Parameter setting error(Err7)
10 Parameters auto measure error(ATER ) 35 Restore factory setting error(Err8)
11 Over Torque(OL3) 36 Reserved
12
Inverter over load( OL2 )
37 Reserved
13 Motor over load(OL1) 38 Parameters copy error via copy unit (EPR1)
14 External communication error(EFO) 39 Parameters copy incorrect via copy unit (EPR2)
15 External stop( E.S ) 40 Inverter over speed(OVSP)
16 Parameters locked(LOC) 41 Input phase lost(PF)
17 Reserved 42 Horsepower setting error(HPERR)
18 Over current at constant speed (OC-C) 43 Reserved
19 Over current during accelerating (OC-A) 44 Motor temperature overheat error(OH4)
20 Over current during decelerating (OC-D) 45 Motor temperature overheat alarm(OH3)
21 Over current at starting to run (OC-S) 46 Output current reaches current limit level(CL)
22 Reserved 47
High Pressure Fault(OPBFT/HIPB)
23 Under voltage during running(LV-C) 48
Low Pressure Fault(LPBFT/LOPB
24 Over voltage during decelerating(OV-C) 49
PID Feedback Signal Loss(FBLSS)