4-10
Group 00- The basic parameters
g
roup
No. Description Range
Factory
Setting
Unit Note
00-00
control mode
0:V/F mode
1:SLV mode
0
-
00-01
Motor rotation
0:Forward
1:Reverse
0 - *1
00-02
Main Run
Source Selection
0:Keypad
1:External Run/Stop Control
2:Communication
1 -
00-03
Alternative Run
Source Selection
0:Keypad
1:External Run/Stop Control
2:Communication
0 -
00-04
Operation modes for
external terminals
0: Forward/Stop-Reverse/Stop
1: Run/Stop-Reverse/Forward
2: 3-Wire Control Mode-Run/Stop
0 -
00-05
Main Frequency
Source Selection
0:Keypad
1:Potentiometer on Keypad
2:External AVI Analog Signal Input
3:External ACI Analog Signal Input
4:External Up/Down Frequency
Control
5:Communication setting Frequency
6:PID output frequency
2 -
00-06
Alternative Frequency
Source Selection
0:Keypad
1:Potentiometer on Keypad
2:External AVI Analog Signal Input
3:External ACI Analog Signal Input
4:External Up/Down Frequency
Control
5:Communication setting Frequency
6:PID output frequency.
0 -
00-07
Main and Alternative
Frequency Command modes
0: Main Or Alternative Frequency
1: Main frequency+Alternative
Frequency
0 -
00-08
Communication
Frequency Command
0.00~599.00 Hz *4
00-09
Frequency command
Save mode
(Communication mode)
0:Save the frequency before power
down
1:Save the communication frequency
0 -
00-10
Initial Frequency
Selection ( keypad mode)
0:by Current Frequency Command
1:by 0 Frequency Command
2:by 00-11
0 -
00-11
Initial Frequency
Keypad mode
0.00~599.00 50.00/60.00 Hz
00-12
Frequency Upper Limit 0.01~599.00 50.00/60.00 Hz
00-13
Frequency Lower Limit 0.00~598.99 0.00 Hz
00-14
Acceleration Time 1 0.1~3600.0
10.0
s
*1
00-15
Deceleration Time 1 0.1~3600.0
10.0
s
*1
00-16
Acceleration Time 2 0.1~3600.0
10.0
s
*1
00-17
Deceleration Time 2 0.1~3600.0 10.0 s *1
00-18
Jog Frequency 1.00~25.00 2.00 Hz *1
00-19
Jog Acceleration Time 0.1~25.5
0.5
s
*1
00-20
Jog Deceleration Time 0.1~25.5
0.5
s
*1