4-33
V/F Maximum output frequency is for VF curve, which can be checked from table when VF curve is
fixed. Maximum output frequency is 01-02 when VF curve is customized, or motor rated frequency
02-06
00-18
Jog Frequency
Range
1.00~25.00Hz
00-19
Jog Acceleration Time
Range
0.1~25.5sec
00-20
Jog Deceleration Time
Range
0.1~25.5sec
The JOG function is operational by using the multi-function input terminals S1 to S5 and setting
the relevant parameters 03-00~03-04 to 6JOG FWD or7JOG REV. Refer to parameter
group 3.