4-29
Group3- preset Frequency function group
03- 00 Acceleration and Deceleration Selection of Multi-Speed
Range
【0】:Part acceleration and deceleration time are set by acceleration and
deceleration time1
【1】:Part acceleration and deceleration time are set by independently
03- 01~03-08 Frequency Setting of Speed-Stage
Range
Preset Speed 0 ~ Preset Speed 7(Hz): =0.00 ~ 400.00
03-17~03-32 Acceleration Time Setting of Multi Speed
Range
Preset Speed 0 ~ 7 Acceleration time(second): =0.1 ~ 3600.0
Preset Speed 0 ~ 7 Deceleration time(second): =0.1 ~ 3600.0
1. When 03-00 is set to 0, Acc-time (Dec-time) is determined by the 00-09/00-10(10-05/10-06).
2.When03-00 is set to 1, Acc-time(Dec-time) is determined by the03-17~03-48.
Function Description:
1) Formula for calculating acceleration and deceleration time:The denominator is base on the rated
frequency of motor (06-04).
Acctime parameter preset frequency
Actual Acctime
Dectime parameter
Actual Dectime
Example:06-04=50hz(motor Rated frequency), 03-02=10hz(preset speed),
03-19=5s(Acc time),03-04=20s(Dectime),
Preset speed 1 Actual Acc time=
03 19 10( )
hz
Preset speed 1 Actual Dec time =
03 20 10( )
hz
2) When 03-00is set to 1,the time has two modes to be set:
Example:00-03=1,01-00=0(s1=RUN/STOP ) ,
01-01=1(s2=forward/reserve),
01-02=2(S3=preset speed1),01-03=3(S4= preset speed 2),
01-03=4(S5= preset speed 4);
mode1:When the run command is uncontinuous, calculate acceleration and deceleration time of each segment like
this
a=
,b =
,c=
,d =
……