EasyManuals Logo

TECO S310+ Series User Manual

TECO S310+ Series
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
4-35
voltage ratio
Fixed VF curve B,C corresponding output voltage is shown belowUintsV
Custom VF curve 00-01 = 7, the default output voltage is shown below
400
V
frequency
Hz
0.50
/
0
.
60
10.00
/
12
.
00
25.00
/
30
.
0
0
50.00
/
60
.
00
Voltage
V
3.8 76.0 190.0 380.0
05- 15 Auto-Torque compensation Filter time coefficient
Range
0.1 ~ 1000.0
05- 16 Auto-Torque compensation gain
Range
0~ 200
05- 17 Auto-Torque compensation frequency
Range
1.00 ~ 5.00Hz
NoteAutomatic torque compensation function need to self-learning under the VF mode (automatic
torque compensation is only applicable to VF mode), the stator resistance of exact gain value (after
06-06), automatic torque compensation will be more precise, if 16 = 0 05 - not for automatic torque
compensation.
00
-
01
B C B C
V
oltage ratio
%
O
utput voltage
1/4
8
6
30.4
22.8
2/5
15
10.5
57.0
39.9
3/6
25
7.7
95.0
29.3

Questions and Answers: