4-35
voltage ratio
Fixed VF curve B,C corresponding output voltage is shown below:(Uints:V)
Custom VF curve 00-01 = 7, the default output voltage is shown below:
frequency
(
)
0.50
/
.
10.00
/
.
25.00
/
.
50.00
/
.
Voltage
(
)
3.8 76.0 190.0 380.0
05- 15 Auto-Torque compensation Filter time coefficient
Range
【0.1 ~ 1000.0】
05- 16 Auto-Torque compensation gain
Range
【0~ 200】
05- 17 Auto-Torque compensation frequency
Range
【1.00 ~ 5.00】Hz
Note:Automatic torque compensation function need to self-learning under the VF mode (automatic
torque compensation is only applicable to VF mode), the stator resistance of exact gain value (after
06-06), automatic torque compensation will be more precise, if 16 = 0 05 - not for automatic torque
compensation.
B C B C