25 
 
3. SETTING USER CONSTANT 
3.1 Frequency command (in Multi-speed operation)  A n - □ □
□ □□ □
□ □  
Under the DRIVE mode, the user can monitor the parameters and set their values. 
Parameter 
No. 
Name  LCD Display (English)  Setting Range  Setting Unit
Factory 
Setting
Ref. 
Page
An-01  Frequency Command 1 
An-01=000.00Hz 
Frequency Command 1 
0.00~400.00 Hz 
0.01Hz  00.00Hz
2-51
2-52
App-3
An-02  Frequency Command 2 
An-02=000.00Hz 
Frequency Command 2 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-03  Frequency Command 3 
An-03=000.00Hz 
Frequency Command 3 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-04  Frequency Command 4 
An-04=000.00Hz 
Frequency Command 4 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-05  Frequency Command 5 
An-05=000.00Hz 
Frequency Command 5 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-06  Frequency Command 6 
An-06=000.00Hz 
Frequency Command 6 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-07  Frequency Command 7 
An-07=000.00Hz 
Frequency Command 7 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-08  Frequency Command 8 
An-08=000.00Hz 
Frequency Command 8 
0.00~400.00 Hz 
0.01Hz  0.00Hz
An-09  Jog Frequency Command
An-09=006.00Hz 
Jog Command 
0.00~400.00 Hz 
0.01Hz  6.00Hz
 
*1. The displayed "Setting Unit” can be changed through the parameter Cn-20. 
*2. At factory setting, the value of "Setting Unit" is 0.01Hz.