37
3.5 Monitoring Parameters U n -
Parameter
No.
Name
LCD Display
(English)
Unit Descriptions
Un-01 Frequency Command
Un-01=60.00Hz
Frequency Command
0.01Hz
Display frequency command, the displayed unit
is determined by Cn-20
Un-02 Output Frequency
Un-02=60.00Hz
Output Frequency
0.01Hz
Display output frequency, the displayed unit is
determined by Cn-20
Un-03 Output Current
Un-03=12.5A
Output Current
0.1A
Display inverter output current
Un-04 Output Voltage
Un-04=220.0V
Output Voltage
0.1V
Display output voltage command of inverter
Un-05 Main Circuit DC Voltage
Un-05=310.0V
DC Voltage
0.1V
Display DC voltage of inverter main circuit
Un-06 Output Power
Un-06= KW
Output Power
0.1KW
Display output power of inverter
Un-07 Output Power Factor
Un-07=0.90
Output P.F.
0.01 Display output power factor of inverter
Un-08 Input Terminal Status
*2
Un-08=00000000
I/P Term. Status
0
0
0
0
0
0
0
0
0OPEN
1CLOSE
Input terminal
1
Input terminal
2
Input terminal
3
Input terminal
4
Input terminal
5
Input terminal
6
Input terminal
7
Input terminal
8
Un-09 Output Terminal Status
*3
Un-09=00000000
O/P Term. Status
0
0
0
0
0
0
0
0
0OPEN
1CLOSE
Relay Contact R2A-
R2C
Opto-contact D01-
DCOM
Opto-contact R1A-
R1C
Reversed
Reversed
Reversed
Reversed
Reversed
Un-10 S/W Version
Un-10=00001
Software Version
Manufacturing use
Un-11 Motor Elapsed Run Hours
Un-11=00001Hr
Elapsed Time
1Hr
Display total time elapsed after pressing RUN
(display data is
esettable)*1
Un-12
Motor Elapsed Energy
KWHR
Un-12=00001Kwh
Elapsed Energy
1Kwh
D
isplay total motor output energy (display data is
esettable)*1

Related product manuals