TM 11-6625-2735-14-1
TABLE 1-1 (cont)
ELECTRICAL
Characteristics
Performance Requirements Supplemental Information
VERTICAL DEFLECTION SYSTEM (cont)
Step Response
Positive-Going Step
Aberrations (0°C to 40°C)
At 5 mV/DIV
Negative-Going Step
Added Mode
Common-Mode Rejection Ratio
(ADD Mode with CH 2 inverted)
Trace Shift as VAR is Rotated
INVERT Trace Shift
Channel Isolation
Position Range
Signal Delay Between CH 1
and CH 2
Maximum Input Voltage
Chopped Mode Repetition Rate
DC coupled: 250 V (DC + peak AC) or
500 V P-P AC at 1 kHz or less
AC coupled: 500 V (DC + peak AC) or
500 V P-P AC at 1 kHz or less.
Approximately 1 MHz.
+4%, –4%, 4% P-P
Add 3% to positive-going step
aberrations.
Add 3% to positive-going step
aberrations.
20:1 at 1 kHz for common-mode sig-
nals of 8 divisions or less.
Adjusts to 2 divisions or less.
Within 1 division from center screen
when switching from normal to in-
verted.
At least 100:1 at 50 MHz.
At least + 12 and - 12 divisions from
graticule center.
0.25 ns or less at 5 mV/DIV
20%, +30%
1-3