CONFIGURATION
111
Internal
Resistance
Settings
Sets the internal resistance of the power supply.
F-08
0.000Ω~0.833Ω(2260B-30-36)
0.000Ω~0.417Ω(2260B-30-72)
0.000Ω~0.278Ω(2260B-30-108)
0.000Ω~5.926Ω(2260B-80-13)
0.000Ω~2.963Ω(2260B-80-27)
0.000~1.975 (2260B-80-40)
0.00Ω~ 55.55Ω (2260B-250-4)
0.00Ω~ 27.77Ω (2260B-250-9)
0.00Ω~ 18.51Ω (2260B-250-13)
0.0Ω~ 555.5Ω (2260B-800-1)
0.0Ω~ 277.8Ω (2260B-800-2)
0.0Ω~ 185.1Ω (2260B-800-4)
Bleeder Control
Bleeder control turns ON/OFF the bleeder
resistor. When set to AUTO the bleeder resistor
is automatically turned on when the output is
turned on and turned off when the output is
turned off. Bleeder resistors discharge the filter
capacitors after power is turned off as a safety
measure.
The AUTO setting is only applicable to
firmware version 1.59 or above.
F-09
0 = OFF, 1 = ON, 2 = AUTO
Buzzer ON/OFF
Turns the buzzer sound on or off. The buzzer is
associated with alarm sounds and keypad entry
sounds.
F-10
0 = OFF, 1 = ON
Measurement
Average Setting
Determines the level of smoothing for the
average setting.
Only available for firmware version 1.5 or
above.
F-17
0 = Low, 1 = Middle, 2 = High

Table of Contents

Other manuals for Tektronix Keithley 2260B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix Keithley 2260B Series and is the answer not in the manual?

Tektronix Keithley 2260B Series Specifications

General IconGeneral
BrandTektronix
ModelKeithley 2260B Series
CategoryPower Supply
LanguageEnglish

Related product manuals