Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
{CRCHeader|CRCTrailer|SYNCFrame|STARTu pnosync|NULLFRStatic|
NULLFRDynamic}
TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Arguments
CRCHeader sets the error type to CRCHeader.
CRCTrailer sets the error type to CRCTrailer.
SYNCFrame sets the error type to SYN
CFrame.
STARTupnosync sets the error type to STARTupnosync.
NULLFRStatic sets the error type to NULLFRStatic.
NULLFRDynamic sets the error type to NULLFRDynamic.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE SYNCFRAME sets the trigger type
is SYNCFRAME.
TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE CRCHEADER indicating the
FlexRay trigger type is CRCHeader.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue
This command specifies the high value when triggering on the FlexRay bus
frame ID field. (Use TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VALue to
set the low value.) The trigger condition needs to be set to IDentifier (using
TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIV ALue <QString>
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIV ALue?
Arguments
<QString> is a quoted string that is the binary frame ID high value.
2-816 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual