Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:FLEXray:FRAMEID:VALue
This command specifies the low value when triggering on the FlexRay bus
frame ID field. (Use TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue to
set the high v
alue.) The trigger condition needs to be set to IDentifier (using
TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VAL ue <QString>
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:VAL ue?
Arguments
<QString> is a quoted string that is the FlexRay frame ID low value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE “1100110010 1” sets the
frame ID value to 11001100101.
TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE ? might return
TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:VALUE "XXXXXXXXXX X" indicating
the frame ID value is don't care.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEType
This command specifies the frame type (normal, payload, null, sync or startup)
when triggering on the FlexRay bus signal. The trigger condition needs to beset
to FRAMEType (using TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:FRAMEType
{NORMal|PAYLoad|NULL|SYNC|STARTup}
TRIGger:A:BUS:B<x>:FLEXray:FRAMEType?
2-818 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual