Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:FLEXray:HEADER:CYCLEcount
This command specifies the cycle count portion of the binary header string when
triggering on the FlexRay bus header. The trigger condition needs to be set to
HEADer (usin
g TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCL Ecount <QString>
TRIGger:A:BUS:B<x>:FLEXray:HEADER:CYCL Ecount?
Arguments
<QString> is a quoted string that is the cycle count portion of the binary header
string.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLEC OUNT “110010” sets the
cycle count to 110010.
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLEC OUNT? might return
TRIGGER:A:BUS:B1:FLEXRAY:HEADER:CYCLEC OUNT "XXXXXX" indicating
the cycle count is don't care.
TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAMEID
This command specifies the frame ID portion of the binary header string when
triggering on the FlexRay bus header. The trigger condition needs to be set to
HEADer (using TRIGger:A:BUS:B<x>:FLEXray:CONDition).
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:FLEXray:H
EADER:FRAMEID <QString>
TRIGger:A:BUS:B<x>:FLEXray:HEADER:FRAM EID?
2-820 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual